Tout savoir sur notre scanner


Tout savoir sur notre scanner

MODEL

Brilliance 64-slice

X-RAY TUBE
X-RAY TUBE ANODE
Heat storage, hu (X-ray tube anode) 8,0,000 (MRC technology)
Heat dissipation rate, hu/min (X-RAY TUBE) 1610000
Tube cooling (X-ray tube anode) Oil/air
Tube focal spot, mm (X-ray tube anode) 0.5 x 1 small, 1 x 1 large
POWER NEEDED 200-500 VAC, 50/60 Hz, 100 kVA, 3-phase
Type (CONFIGURATION) Multislice
# of slices (X-ray tube anode) 64
IMAGE PROCESSING (MAXIMUM DISPLAY)
Cpu (NETWORK/DATABASE) Intel, Windows OS
Scan fovs, cm (IMAGE PROCESSING) Up to 50
Image reconstruction matrixes (IMAGE PROCESSING) 256 x 256, 512 x 512; optional 768 x 768, 1024 x 1024
Reconstruction time
Per slice, sec (Reconstruction time) Up to 40 images/sec with 3-D cone beam
For localization scan, sec (Reconstruction time) 5
HELICAL SCANNING (DISPLAY) Yes
Max scan time, sec (DISPLAY) 100
Max scan volume, cm (DISPLAY) 162
Spatial resolution, lp/cm (DISPLAY) 24
Pitch (DISPLAY) 0 to 1.5, user selectable
Reconstruction time per image, sec (DISPLAY) 0.025, 3-D cone beam
SCORING OF CORONARY ARTERY CALCIFICATION (IMAGE STORAGE) Yes
TABLE FEATURES
Range of movement
Vertical, cm (Range of movement) 52-104
Longitudinal, cm (Range of movement) 190
Scanning range,cm (Range of movement) 162
Max. patient weight, (precision), kg (Range of movement) 204 (±0.25 mm)
GENERATOR
Output, kw (X-RAY GENERATORS) 60
Kvp range (GENERATOR) 80,120, 140
Ma range (IMAGING SYSTEM) 28in 1 mA increments
DISPLAY
MONITOR 18″ flat LCD 2
Matrixes, pixels (DISPLAY) 1280 x 1024
Range of ct numbers (DISPLAY) -1,000 to +3,095
Image enlarging scale (DISPLAY) Up to 10x; real time
DICOM 3.0 COMPATIBLE (POWER NEEDED, VAC) Yes
Image storage
Hd capacity, gb (IMAGE STORAGE) 292
No. online images (IMAGE STORAGE) 514,242 uncompressed (512 x 512)
Archive (IMAGE STORAGE) 9.1 GB rewritable EOD, 620 MB CD
PERFORMANCE
High-contrast spatial resolution 0% mtf, lp/cm (PERFORMANCE) 24
Low-contrast resolution, mm at % at <=4 rads (PERFORMANCE) 4 at 0.3%
Sound, % at <= 2.5 rads (PERFORMANCE) 0.27
FLOOR SPACE NEEDED
Size, m2 (FLOOR SPACE NEEDED) 25.9
GANTRY
Geometry (GANTRY) Rotate-rotate
DETECTOR (SCATTERED LIGHT) 40 mm z-axis coverage, solid-state GOS
Rows (GANTRY) 64
Elements/row (GANTRY) 672
# detection channels (GANTRY) 43,008 elements 1
Rotation times, sec 360 (GANTRY) 0.5,0.75,1,1.5, 2; optional 0.4
Partial (GANTRY) 0.33; opt 0.28
Slice thickness, mm (GANTRY) 0.5-10 variable
X-ray fan beam angle, ° (GANTRY) 54.4
Gantry angle deg (GANTRY) ±30
Gantry size, hxwxd,cm (GANTRY) 203 x 239 x 94
Gantry weight, kg (GANTRY) 1764
Gantry opening, cm (GANTRY) 70
Scan localizer (GANTRY) Laser
OTHER ATTRIBUTES (Interference compensation) Spiral AutoStart, isotropic imaging, functional imaging (perfusion), calcium scoring, cardiac imaging, Dental CT, bone mineral analysis (Q-BMAP), CT endoscopy, lung nodule assessment, stenosis analysis, stent planning, true 64channel with 40-mm coverage,
FDA CLEARANCE (Interference compensation) Yes
CE MARK (MDD) (Interference compensation) Yes
MARKETING REGION (Interference compensation) Worldwide

Les spécifications du fabricant ci-dessous vous intéressent peut-être:

Responsabilité

L’information contenue dans cette page pourrait être partielle, incomplète, ou contenir des erreurs et des informations inexactes.
MedWOW décline toute responsabilité ou obligation qui dépendrait du contenu de cette page.


Leave a Reply


ScanvetLyon – MERMOZ Vet

Logo Scanvet

Coordonnées

Adresse :
MERMOZ Vet
76, rue Marius BERLIET 69008 LYON

Tél. : 04 27 01 87 94

Parking privé en sous-sol
Rue Saint-Gervais (accès direct à la clinique)

Copyright. Mermoz Vet. Maintenance et création : VetactionConseil.com / 2017